Lighting and switches
Can this smart plug safely run my heater / kettle / AC?
Usually yes for a heater or a kettle, and it depends for an air conditioner — because resistive and motor loads are not the same question, and only one of the four makers we read publishes a different amp rating for each.
Before-you-buy check · Published · Desk research, not tested
Usually, for a heater or a kettle: both are resistive loads, and that is the load type every maker rates highest. An air conditioner is a different question, because its compressor is a motor load, which Amazon's own smart plug rates at barely two-thirds of its resistive figure — and three of the four plugs we read publish no motor or inductive figure at all. Check your appliance's own nameplate watts against the maker's figure for your load type, not the plug's headline number.
What would change this answer
A maker publishing a new load-type breakdown, or a plug with a published inrush or start-current rating — none of the four here state one today. Converting watts to amps at your own voltage (check 2) is arithmetic, not a figure that goes stale; what can change is which published number you are comparing it against.
Work on mains wiring is a licensed job in most places, and in some it is unlawful for anyone else to do it. Nothing on this page is electrical advice: it is about reading what the makers publish about their own products, and about reading what is already in your switch box with the power off at the consumer unit or breaker panel. Where a step means connecting a wire, that is the point at which the makers themselves tell you to use a qualified electrician, and so do we.
One box, two different questions
A smart plug’s packaging prints one headline figure — 15 A, or 1800 W — and it is tempting to read that as a single ceiling that covers anything you plug in. It is not. A resistive load like a heater or a kettle’s element draws a steady current with no surprises, and that is the load type the headline figure almost always describes. A motor or a compressor — most of what makes an air conditioner an air conditioner — is a different load type, and the maker’s own document is the only place that says whether, and by how much, the real ceiling for that case is lower.
The checks, in order
Five checks. The second one is the only arithmetic on this page, and everything after it depends on having done it with your own numbers.
Check 1 — Read the appliance's own nameplate, not the plug's box
Heaters, kettles and most appliances print a running wattage or amperage on a label somewhere on the body or the cord — not the plug you are about to buy. A 1500 W figure is common for a space heater or a kettle; a window air conditioner's nameplate usually gives amps directly.
If the answer is no: If the appliance gives amps and not watts, or watts and not amps, that is check 2 below — one line of arithmetic converts between them, and you need both numbers before the next check means anything.
Check 2 — Convert to amps at your own mains voltage
Amps = watts ÷ volts. A 1500 W heater on a 120 V circuit draws 1500 ÷ 120 = 12.5 A. The same 1500 W heater on a 230 V circuit draws 1500 ÷ 230 ≈ 6.5 A — the voltage you actually have changes the answer, so use yours, not a figure from a page written for the other one.
If the answer is no: There is no "if no" here: this is the one calculation every check after it depends on, worked from numbers you read off your own appliance and your own supply.
Check 3 — Work out whether the appliance is a resistive load or not
A plain heating element — a space heater, a kettle, an incandescent bulb — is a resistive load: steady current, no starting surge. Anything with a motor or a compressor, which is most air conditioners, most fridges, and some fan-assisted heaters, is an inductive or motor load instead. Shelly's own published load types name the same split: “Resistive (incandescent bulbs, heating devices)” against “Inductive (LED light drivers, transformers, fans, refrigerators, air-conditioners)”.
If the answer is no: If you cannot tell from the appliance itself, the nameplate's own wording is the fastest check: anything that lists a starting or locked-rotor current alongside a running current has a motor in it, and a plain heater or kettle never does.
Check 4 — Compare your amp figure against the maker's figure for that load type, not the headline number
The table below is the comparison. Amazon's own Smart Plug publishes a different maximum for each load type on the same device — 15 A resistive, but only 10 A inductive and 1/2 HP motor. A heater or kettle at 12.5 A clears the resistive figure; the same plug running an air conditioner has to clear the lower inductive or motor figure instead, which several appliances will not.
If the answer is no: Where a maker publishes one blended number with no load-type split at all — TP-Link's KP125 and SwitchBot's Plug Mini both do this, stating only “15A” or “15 A resistive load maximum” — that is the honest limit of what you can check from the document. A single published figure with no resistive/inductive split does not mean the device is rated for everything up to that number; it means the maker has not told you where the ceiling drops for a motor or compressor, and the safer reading is to treat it as a resistive-only figure.
Check 5 — Know the one thing none of these documents publish: the starting surge
A compressor or motor draws several times its running current for a fraction of a second at switch-on. None of the four plugs in the table below publish a start or inrush current figure for what you plug into them — only Shelly even names the mechanism, by listing "motor start capacitors" under its capacitive load type.
If the answer is no: This is a printed absence, not a pass: a plug sitting just under its inductive or motor ceiling on running current can still trip on the surge at the moment it switches an air conditioner's compressor on. None of the makers below say otherwise, and neither do we — it is the one figure this page cannot give you.
Why only one maker splits the number at all
Read down the table and three of the four plugs publish exactly one figure, no load type attached. That is not the same as a plug being rated for everything up to that number — it is the limit of what the document tells you. Amazon’s own Smart Plug is the exception: the same physical device carries a 15 A resistive figure, a 10 A inductive figure and a 1/2 HP motor figure side by side, which is the clearest published evidence in this set that a motor load is not simply a smaller resistive load — it is rated separately because it behaves differently.
Shelly’s Plus Plug S takes the opposite approach to the same problem: one published amperage, 12 A, but the most specific load-type list of the four, naming “air-conditioners” explicitly under its inductive category rather than leaving the reader to guess which bucket an AC unit falls into.
The honest limit of this page
Running current is not the whole picture for anything with a motor or a compressor. A compressor can pull several times its running current for a fraction of a second at switch-on, and none of the four documents we read publish a start or inrush current figure— that gap exists in the makers’ own specifications, not only in this summary of them. A plug sitting comfortably under its published inductive or motor ceiling on running current can still trip at the moment a compressor starts, and the only way to find out is the same way you’d find out for any appliance: by trying it, with the plug’s own overload protection as the backstop if the figure was wrong.
Which shape of device suits the socket in the first place — bulb, switch or plug — is the bulb, switch or plug comparison, and a plug with no neutral problem to solve is exactly why it is route 4 in the no-neutral options page.
| Maker | Model | Resistive, inductive and motor load limits, as published | Source, and the date we read it |
|---|---|---|---|
| Amazon | Smart Plug (model C2YY37) | “Output: 120 V ~, 60 Hz, 15 A, resistive load” — then separately “10 A, inductive load”, “1/2 HP, motor load”, and “600W (TV-5), incandescent”. The only maker here that publishes a different figure for each load type on the same device. | Amazon Smart Plug (model C2YY37) Safety & Compliance page — “Input: 120 V ~, 60 Hz, 15 A max”; “Output: 120 V ~, 60 Hz, 15 A, resistive load”; “120 V ~, 60 Hz, 10 A, inductive load”; “120 V ~, 60 Hz, 1/2 HP, motor load”; “120 V ~, 60 Hz, 600W (TV-5), incandescent” — read 2026-11-22 |
| SwitchBot | Plug Mini (HomeKit-enabled) | “Output: 1875 W 15 A resistive load maximum.” The document states “resistive load” explicitly but publishes no separate inductive or motor figure — a device with a motor is outside what this page documents, not inside it at a lower number. | SwitchBot, Plug Mini (HomeKit-enabled) product page, Specifications — “Input: 100 - 125 V AC 50 / 60Hz” “Output: 1875 W 15 A resistive load maximum”. No inductive or motor load figure is published for this model — read 2026-11-22 |
| TP-Link | Kasa KP125 | “Maximum Load 15A, 1800W.” No load type is named at all, resistive or otherwise — the single figure is the entire published spec. | TP-Link, KP125 Kasa Smart Wi-Fi Plug Slim, Energy Monitoring — product specification page: “Working Status Input 100-120V~, 50/60Hz Rated 100-120V~, 50/60Hz Maximum Load 15A, 1800W”. No resistive, inductive or motor breakdown is published for this model — read 2026-11-22 |
| Shelly | Plus Plug S | “Max switching current AC: 12 A” at “Max switching voltage AC: 260 V” — the lowest headline amperage here, on a 230 V-market device. Its own supported-load-types list is the most specific in the table: resistive, capacitive and inductive each named with examples, air conditioners included under inductive. | Shelly knowledge base, “Shelly Plus Plug S V1” — “Max switching current AC: 12 A”; “Max switching voltage AC: 260 V”; “Supported load types Resistive (incandescent bulbs, heating devices) Capacitive (capacitor banks, electronic equipment, motor start capacitors) Inductive (LED light drivers, transformers, fans, refrigerators, air-conditioners)” — read 2026-11-22 |
Not a ranking. The order is the published resistive-load figure, because every maker here publishes one; a lower number is not a worse plug, it is a different market voltage and a different design target. No row carries a purchase link: there is no commercial relationship behind this site and no affiliate account, so a row's only link is the maker's own document.
Nobody here has plugged an appliance into any of these four plugs, metered an actual draw, or tested a trip threshold. Every figure below is quoted from the maker's own specification, safety page or knowledge-base article with the date we read it, and the table covers four plugs read on 22 November 2026 — not a market survey. Where a maker publishes no inductive or motor figure, that absence is stated as the finding; it is not us assuming the device is unsafe for that load, and it is not the maker saying it is safe either.
Sources
Each specification on this page came from one of these documents, and each is listed with the date it was read.
- Amazon Smart Plug (model C2YY37) Safety & Compliance page — “Input: 120 V ~, 60 Hz, 15 A max”; “Output: 120 V ~, 60 Hz, 15 A, resistive load”; “120 V ~, 60 Hz, 10 A, inductive load”; “120 V ~, 60 Hz, 1/2 HP, motor load”; “120 V ~, 60 Hz, 600W (TV-5), incandescent”
https://www.amazon.com/gp/help/customer/display.html?nodeId=G7G62UBRDKWDK5K7 — read
- Shelly knowledge base, “Shelly Plus Plug S V1” — “Max switching current AC: 12 A”; “Max switching voltage AC: 260 V”; “Supported load types Resistive (incandescent bulbs, heating devices) Capacitive (capacitor banks, electronic equipment, motor start capacitors) Inductive (LED light drivers, transformers, fans, refrigerators, air-conditioners)”
https://kb.shelly.cloud/knowledge-base/shelly-plus-plug-s — read
- TP-Link, KP125 Kasa Smart Wi-Fi Plug Slim, Energy Monitoring — product specification page: “Working Status Input 100-120V~, 50/60Hz Rated 100-120V~, 50/60Hz Maximum Load 15A, 1800W”. No resistive, inductive or motor breakdown is published for this model
https://www.tp-link.com/us/home-networking/smart-plug/kp125/v1/ — read
- SwitchBot, Plug Mini (HomeKit-enabled) product page, Specifications — “Input: 100 - 125 V AC 50 / 60Hz” “Output: 1875 W 15 A resistive load maximum”. No inductive or motor load figure is published for this model
https://us.switch-bot.com/pages/switchbot-plug-mini-homekit-enabled — read
Checked
Written from published specifications, manuals and install guides, each named where it is used. Nobody here has handled this device. How we work.